all
Bands
2 kW
Output
Frequency1.5 - 700 MHz
TX power2000 W (Power handling 2 kW on HF (375 W at VHF). The power_w lists the 2 kW HF figure. It is a DC-blocked gas-tube design (no DC continuity through the center pin).)
Modesn/a
Connectors
rfType N female on both ends (50 ohm); flange/bulkhead mount to a ground panel.
groundBolts to a grounded entry panel - effectiveness depends on a low-impedance single-point ground.
power reqNone - a passive in-line surge protector (must be properly grounded).
Coaxial RF lightning/surge protector for 1.5-700 MHz, 50 ohm Power handling 2 kW HF (375 W VHF) DC-blocked, specially configured gas-tube design - no DC continuity between center pins 50 kA surge current capability; let-through energy ~3.5 mJ 1.1:1 VSWR with blocking-cap technology Soft turn-on bleeds static charge quietly (without adding receiver noise) Flange mount with Type N female connectors; REACH/RoHS compliant
Strengths

A professional-grade coax lightning protector: the DC-blocked gas-tube design handles a huge 50 kA surge with very low let-through energy while keeping VSWR at 1.1:1 and adding negligible loss, and its soft turn-on bleeds static without injecting receiver noise. Flange mounting to a grounded entry panel is exactly how a proper single-point-ground station is built. Rated 2 kW on HF.

Weaknesses

It only works as part of a proper grounding system - bolted to a low-impedance single-point ground/entry panel - so it is not a plug-and-forget device, and the DC-blocked design will not pass DC bias or control voltages (use a DC-pass model for remote tuners/preamps). It uses N connectors (adapters needed for SO-239 stations), and gas tubes degrade after major hits.

Verdict

The PolyPhaser IS-50NX-C0 is a benchmark coax lightning protector - 50 kA capability, DC block and low let-through with 2 kW HF handling - for stations built around a proper single-point ground. The right choice where you need serious surge protection and do not need to pass DC.

The PolyPhaser IS-50NX-C0 is a professional-grade coaxial lightning/surge protector - the kind of device that belongs where your feedline enters the building. It covers 1.5 to 700 MHz at 50 ohms, handles 2 kW on HF (375 W at VHF), and uses a DC-blocked, specially configured gas-tube design: there is no DC continuity between the input and output center pins, which (with its blocking-cap technology and 'soft turn-on') lets it bleed slow static build-up quietly while clamping fast surges. It is rated for a 50 kA surge with very low let-through energy (~3.5 mJ), all while maintaining a 1.1:1 VSWR and negligible loss.

Mechanically it is a flange-mount unit with Type N female connectors on both ends, designed to bolt to a grounded entry panel so both connectors sit parallel to the surface - exactly how a proper single-point-ground (bulkhead) station is constructed.

The key point is that a protector like this is only as good as the ground it is bolted to: it must connect to a low-impedance single-point ground to do its job, so it is part of a system rather than a standalone gadget. Its DC-blocked design also means it will not pass DC bias or control voltages, so for a remote auto-tuner or a DC-powered preamp you need a DC-pass model instead; it uses N connectors (adapters for SO-239 stations); and gas tubes should be replaced after a major strike. Where you need serious protection without passing DC, it is a benchmark. Compare it with the DC-passing Alpha Delta Transi-Trap and the surge-protected Alpha Delta DELTA-4B switch.